MPRXCX® FLEXISHIP EMC 0.6/1kV 3 x 50

Description

Description

Standards

  • International
    IEC 60092-350; IEC 60092-353; IEC 60092-360; IEC 60228; IEC 60332-3-22; IEC 60754-1; IEC 60754-2; IEC 61034

Application

Motor supply cables for frequency converters controlled low voltage AC drives on ships called VFD applications.

These MPRXCX® FLEXISHIP EMC cables are shielded with a 100% coverage copper polyester tape which ensure a high EMC protection. MPRXCX® FLEXISHIP EMC type withstands IEC 60332-3-22 fire test on bunched cables and performs to the SOLAS requirements.

Design

All materials used to produce this cable are halogen free. This design ensures that non corrosive and low toxic gases are emitted in case of fire. Therefore, this cable type is especially designed for installations on passenger ships.

  1. Conductor:
    Flexible bare copper
    Class 5
  2. Insulation:
    XLPE (cross linked polyethylene)
  3. Optional
    Return earth conductor
  4. Inner covering:
    (Filler if necessary) 
    Lapped or extruded
  5. Screen / Armouring:
    Copper / Polyester tape
    Bare copper braid
  6. Outer sheath:
    Polyolefin SHF1 (SHF2 on request)
    Colour: black

 

Core identification

3 cores : black - white - brown

 

Marking

I NEXANS I MPRXCX FLEXISHIP EMC "voltage" "n" x "s" mm² 90C IEC 60332-22 "WW/YY" + metric marking

 

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Bare copper
Conductor flexibility
Flexible class 5
Insulation
XLPE (Cross-linked Polyethylene)
Screen
Copper tape
Armour type
Bare copper braid
Outer sheath
Polyolefin
Sheath colour
Black
With Green/Yellow core
Yes
Construction type
-
Halogen free
-

Dimensional characteristics

Dimensional characteristics

Number of cores
3
Conductor cross-section
50 mm²
Minimum outer diameter
30.5 mm
Maximum outer diameter
34.5 mm
Approximate weight
2266 kg/km
Nominal outer diameter
31.3 mm

Electrical characteristics

Electrical characteristics

Permissible current rating in open air
137 A
Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Usage characteristics

Usage characteristics

Fire retardant
EN IEC 60332-3-22 (cat A)
Flame retardant
IEC 60332-1
Gases corrosivity
IEC 60754-2
Smoke density
IEC 61034
Electro magnetic interference resistance
Yes
Operating temperature, range
-30 ... 80 °C
Max. conductor temperature in service
90 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close